GetExitCodeProcess info  Overview  Group

The GetExitCodeProcess function retrieves the termination status of the specified process.

BOOL GetExitCodeProcess(

    HANDLE hProcess,

// handle to the process

    LPDWORD lpExitCode 

// address to receive termination status

   );

Parameters

hProcess
Identifies the process.

Windows NT: The handle must have PROCESS_QUERY_INFORMATION access. For more information, see Process Objects.

lpExitCode
Points to a 32-bit variable to receive the process termination status.

Return Values

If the function succeeds, the return value is nonzero.

If the function fails, the return value is zero. To get extended error information, call GetLastError.

Remarks

If the specified process has not terminated, the termination status returned is STILL_ACTIVE. If the process has terminated, the termination status returned may be one of the following:

See Also

ExitProcess, ExitThread, TerminateProcess, WinMain


file: /Techref/os/win/api/win32/func/src/f31_14.htm, 3KB, , updated: 2001/9/3 22:53, local time: 2024/11/30 20:56,
TOP NEW HELP FIND: 
3.133.139.28:LOG IN

 ©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions?
Please DO link to this page! Digg it! / MAKE!

<A HREF="http://massmind.ecomorder.com/techref/os/win/api/win32/func/src/f31_14.htm"> GetExitCodeProcess</A>

After you find an appropriate page, you are invited to your to this massmind site! (posts will be visible only to you before review) Just type a nice message (short messages are blocked as spam) in the box and press the Post button. (HTML welcomed, but not the <A tag: Instead, use the link box to link to another page. A tutorial is available Members can login to post directly, become page editors, and be credited for their posts.


Link? Put it here: 
if you want a response, please enter your email address: 
Attn spammers: All posts are reviewed before being made visible to anyone other than the poster.
Did you find what you needed?

 

Welcome to ecomorder.com!

 
Quick, Easy and CHEAP! RCL-1 RS232 Level Converter in a DB9 backshell
Ashley Roll has put together a really nice little unit here. Leave off the MAX232 and keep these handy for the few times you need true RS232!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  .